Monarch 5396-0515 Track-It DC Current Data Logger, 20 mA

Model: 5396-0515

Monarch 5396-0515 Track-It DC Current Data Logger, 20 mA

Model: 5396-0515

A two-channel, battery-powered, and stand-alone data logger that records up to 32,000 samples of DC current data, and features a current range of 20 mA, and accuracy of ±0.5%. It is easily configured using Track-It™ software and can be used to record ambient temperature if one or neither input is being used.

A two-channel, battery-powered, and stand-alone data logger that records up to 32,000 samples of DC current data, and features a current range of 20 mA, and accuracy of ±0.5%. It is easily configured using Track-It™ software and can be used to record ambient temperature if one or neither input is being used.

Regular Price $144.00 USD
Availability 1 Week
Quantity

Traceable In-House Calibration Certificate for your 5396-0515 Track-It DC Current Data Logger

Traceable In-House Calibration Certificate for your 5396-0515 Track-It DC Current Data Logger

Monarch 5396-0515 Offers

The unit is easily set up using the included Track‐It™ Software. Simply plug the logger into an open USB port on your PC, and the software automatically identifies the logger. Configure the unit to start and stop recording at a predetermined time and date, or only when an alarm condition is sensed. The sample storage rate can be set from 1 sample every 2 seconds, up to 1 sample every 24 hours. The onboard data storage is non‐volatile, so data will not be lost in the event of a depleted battery.

The information displayed on the LCD is user programmable and can be sequenced by pressing the logger button, and a multicolored LED indicator notifies the user of alarms or general activity.

Features

  • Push button to start recording immediately or program to start recording at a later time and date
  • Up to 64,000 samples per recording session
  • 20 mA current range
  • ±0.5% accuracy
  • Multiple alarm set points
  • Compact size
  • Integral USB interface/connector (no cable required)
  • Powerful interactive Track-It Software package
  • High accuracy and repeatability
  • Accurate internal clock (1 minute/year)
  • Multiple user programmable displays
  • One year battery life

Applications

  • Industrial process monitoring
  • Trouble shooting problematic signals
  • Productivity monitoring
  • Remote indication

Track-It™ software

Track‐It™ Software is a powerful Windows based software package. It allows for easy setup, retrieval, interpretation and export of the recorded data. Simply connect your Track‐It™ data logger to an open USB port and begin communicating immediately.

  • Point and click to select your sample interval, alarm set points, engineering units, recording triggers and LCD Displays
  • Monitor and record any voltage or current device
  • Scale directly to your engineering units such as flow, pressure, PH, vibration, temperature, gases, control outputs
  • View a numerical data table or graphical representation of data readings relative to time
  • Use the graph tools such as zoom, cursor, min and max to examine and analyze the record
  • Export stored data into an Excel spreadsheet

Monarch 5396-0515 Specifications

Record Sample rates: User configured 1 every 2 seconds up to 1 every 24 hours
Number of samples: 32,000 or 64,000 (depends on setup)
Record Trigger Two independent triggers
Multiple trigger modes: Instantaneous, button control, on alarm, time and date (start and stop), day of week
Record Mode Fill to end of memory, cyclic, number of samples, time duration
Display 4 digit LCD (Non display versions available with LED only)
User programmable: Indication of data value, eng units, alarms, record mode, battery condition, time/date, memory
LED User programmable: Indication of alarms, recording, triggered
Button User programmable: View display, record on/off, reset alarms
Alarms 2 user programmable alarms. High or Low
Communication Direct USB connection
Software Track-It™ Software - Program device, view recorded data, export to Excel. Simple and advanced modes
Battery Type: Lithium CR2032
Life: 1 year at 1 minute sample rate
Temperature Range -4 to 158°F (-20 to 70°C)
Accuracy ±0.5°C 32 to 122°F (0 to 50°C)
±2°C -4 to 185 F (-20 to 85°C)
Resolution 0.11°F (0.06°C)
Clock Accuracy ±1 minute/year
Dimensions 4.06 x 0.66 x 1.00" (10.32 x 1.67 x 2.54 cm)
Click here for complete specifications on the Monarch 5396-0515

What's included with the Monarch 5396-0515

  • Data Logger
  • Current Input Module
  • Battery
  • Track-It™ Software

Ask a question about Monarch 5396-0515 Track-It DC Current Data Logger, 20 mA

Customer Reviews for the Monarch 5396-0515

Monarch 5396-0515 Offers

The unit is easily set up using the included Track‐It™ Software. Simply plug the logger into an open USB port on your PC, and the software automatically identifies the logger. Configure the unit to start and stop recording at a predetermined time and date, or only when an alarm condition is sensed. The sample storage rate can be set from 1 sample every 2 seconds, up to 1 sample every 24 hours. The onboard data storage is non‐volatile, so data will not be lost in the event of a depleted battery.

The information displayed on the LCD is user programmable and can be sequenced by pressing the logger button, and a multicolored LED indicator notifies the user of alarms or general activity.

Features

  • Push button to start recording immediately or program to start recording at a later time and date
  • Up to 64,000 samples per recording session
  • 20 mA current range
  • ±0.5% accuracy
  • Multiple alarm set points
  • Compact size
  • Integral USB interface/connector (no cable required)
  • Powerful interactive Track-It Software package
  • High accuracy and repeatability
  • Accurate internal clock (1 minute/year)
  • Multiple user programmable displays
  • One year battery life

Applications

  • Industrial process monitoring
  • Trouble shooting problematic signals
  • Productivity monitoring
  • Remote indication

Track-It™ software

Track‐It™ Software is a powerful Windows based software package. It allows for easy setup, retrieval, interpretation and export of the recorded data. Simply connect your Track‐It™ data logger to an open USB port and begin communicating immediately.

  • Point and click to select your sample interval, alarm set points, engineering units, recording triggers and LCD Displays
  • Monitor and record any voltage or current device
  • Scale directly to your engineering units such as flow, pressure, PH, vibration, temperature, gases, control outputs
  • View a numerical data table or graphical representation of data readings relative to time
  • Use the graph tools such as zoom, cursor, min and max to examine and analyze the record
  • Export stored data into an Excel spreadsheet

Monarch 5396-0515 Specifications

Record Sample rates: User configured 1 every 2 seconds up to 1 every 24 hours
Number of samples: 32,000 or 64,000 (depends on setup)
Record Trigger Two independent triggers
Multiple trigger modes: Instantaneous, button control, on alarm, time and date (start and stop), day of week
Record Mode Fill to end of memory, cyclic, number of samples, time duration
Display 4 digit LCD (Non display versions available with LED only)
User programmable: Indication of data value, eng units, alarms, record mode, battery condition, time/date, memory
LED User programmable: Indication of alarms, recording, triggered
Button User programmable: View display, record on/off, reset alarms
Alarms 2 user programmable alarms. High or Low
Communication Direct USB connection
Software Track-It™ Software - Program device, view recorded data, export to Excel. Simple and advanced modes
Battery Type: Lithium CR2032
Life: 1 year at 1 minute sample rate
Temperature Range -4 to 158°F (-20 to 70°C)
Accuracy ±0.5°C 32 to 122°F (0 to 50°C)
±2°C -4 to 185 F (-20 to 85°C)
Resolution 0.11°F (0.06°C)
Clock Accuracy ±1 minute/year
Dimensions 4.06 x 0.66 x 1.00" (10.32 x 1.67 x 2.54 cm)
Click here for complete specifications on the Monarch 5396-0515

What's included with the Monarch 5396-0515

  • Data Logger
  • Current Input Module
  • Battery
  • Track-It™ Software

Ask a question about Monarch 5396-0515 Track-It DC Current Data Logger, 20 mA

Customer Reviews for the Monarch 5396-0515

More Monarch Products

Calibration Lab